Brand: |
Mitsubishi |
Model Number: |
MR-J2S-10B1-PF090T016 |
Country Of Origin: |
Japan |
Warranty: |
1year |
Rated Current [A: |
1.5a |
Allowable Voltage Fluctuation: |
Three-phase Or Single-phase AC170 V ~ 264 V |
POWER: |
100W |
Output: |
170V 0-360Hz 1.1A |
High Light: |
1.1A Mitsubishi Servo Drives
,
100W Mitsubishi Servo Drives
,
MR-J2S-10B1-PF090T016
|
Mitsubishi Servo Drives 100W 170V 0-360Hz 1.1A MR-J2S-10B1-PF090T016
Product Specifications:
Brand Name |
Mitsubishi |
Model No. |
MR-J2S-10B1-PF090T016 |
Type |
Servo Drives |
Condition |
New |
-
Series name : MELSERVO-24 series
-
Command interface : General-purpose interface
-
Voltage class : 200V
-
Motor rated output [KW] : 0.75
-
Servo amplifier form name :MR-J2S-10B1-PF090T016
-
Rated current [A] : 5.8
-
Voltage and frequency (Note 1) : Three-phase or single-phase AC200 V ~ 240 V, 50 Hz / 60 Hz
-
Rated current (Note 14) [A] : 3.8
-
Allowable voltage fluctuation : Three-phase or single-phase AC170 V ~ 264 V
-
Allowable frequency fluctuation : Within ± 5%
-
Voltage and frequency : Single-phase AC200 V ~ 240 V, 50 Hz / 60 Hz
-
Rated current [A] : 0.2
-
Allowable voltage fluctuation : Single-phase AC170 V ~ 264 V
Environmental condition :
Ambient temperature : Operation: 0 ° C ~ 55 ° C (no freezing), storage: -20 ° C ~ 65 ° C (no freezing)
Ambient humidity : Operation / storage: 90% RH or less (non-condensing)
Atmosphere : Indoors (no direct sunlight), that there is no corrosive gas, flammable gas, oil mist, dust and dirt
elevation : Above sea level 2000 m or less (Note 18)
Vibration resistance : 5.9 m / s 2, 10 Hz ~ 55 Hz (X, Y, Z each direction)
Safe performance :-
Third party certification standards : EN ISO 13849-1 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2 (Note 20)
Response performance : 8 ms or less (STO input off → energy cut-off)
Test pulse input (STO) (Note 7) : Test pulse interval: 1 Hz ~ 25 Hz, test pulse off time: Up to 1 ms
Expected average dangerous failure time (MTTFd) : MTTFd ≧ 100 [year] (314a)
Diagnostic coverage (DC) : DC = medium (Medium), 97.6 [%]
The average probability of a dangerous failure (PFH) : PFH = 6.4 × 10 -9 [1 / h]
Overseas Compliance : The correspondence to the international standards and laws
Structure (protection grade) :- : A little over cold, open (IP20)