Introduction1. One trolley structure, convenient transportation.2. Without complex wiring, through the weak internal control of high voltage switch for automatic switch.3. For 220V - 220KV Power cable of low resistance, high resistance leakage fault, flashover failure for rapid positioning and fixed pointFeatures:1. Four gear test mode switch through the low voltage elv intelligent control.2. DC voltage up to 16KV.3.8/16KV,every voltage grade can reach the output of 1000J impact energy.Technical parameter1. test mode: the arc reflection method (multiple pulse), current sampling, the attenuation law (voltage sampling method), DC output.2.sampling signal types: arc reflection method (multiple pulse), current sampling, the attenuation law (voltage sampling method, low voltage pulse).3. DC high voltage output:0 ~ 16KV negative, maximum output current: 76mA0 ~ 8KV negative, maximum output current: 152mA4.Impact of capacitor: 0 ~ 16KV 7.5uF, maximum output energy:1000J0 ~ 8KV 30uF, maximum output energy:1000J5. the ball gap discharge: weak control of discharge period 3 - 12 seconds adjustable, and specially designed silencer, meet the beginning end of cable fault need to mute the requirements.6. protection:The position of zero voltage protection: to prevent error operation, the safeguard of the person and the tested product safety;According to the "off" button, the safety device is provided by the remaining charge, automatic release, guarantee the safety
7.selec the extension cable, can became a vehicle type cable fault location system.