Applicable Industry
JOEO Salt Spray Chamber (CCT) series of chambers are the industry’s most advanced, flexible and robust test chambers available anywhere in the world.Salt Spray Chamber can provide the user a wide range of controlled cycles to meet the greatest variety of Industry standard specifications.
Salt Fog Test DIN EN ISO 9227 – DIN 50 021
Condensed Water Test DIN EN ISO 6270-2 – DIN 50 017 and EN ISO 6988 – DIN 50 018
Standard Climate DIN 50 014, clause 5 ambient temperature
Structure
Salt spray chamber adopts 5mm or 8mm imported gray and white impact resistant P.V.C board, with high temperature resistance up to 85℃ and corrosion resistance.
Support frame: ¢ 10MM fiberglass rod, corrosion resistant. The steel V-frame and the fiber rod angle are placed to ensure the specimen is inclined at 15-30 degrees.
Pressure barrel is welded seamlessly with 2.0mm SUS304 stainless steel plate
- Salt spray chamber with color touch screen LCD controller, which can record the testing curves.
- Program Group Capacity: 140Pattern (Group) 1400Step (above) each program can be set up to Repest99 segment.
- Each executive mode time can be arbitrarily set 0-999 hours, 59 minutes.
- Each group can be arbitrarily set the cycle of 1-999 .
- Has the power memory function, recovery after power continue to perform the not completed the test.
- interface RS232 connect with computer.
Fields Testing Standards
- GB/T 20854-2007 Dry and wet salt spray test
- ISO14993-2001 Dry and wet salt spray test
- GB/T 2423.17-1993 salt spray test
- GB/T 2423.18-2000 salt spray test
- GB/T 10125-1997 salt spray test
- ASTM.B117-97 salt spray test
- JIS H8502 salt spray test
- IEC68-2-11 salt spray test
- IEC68-2-52 1996 salt spray test
- GB.10587-89 salt spray test
- CNS.4158 salt spray test
- CNS.4159 CASS Copper accelerated acid salt spray test
- GB/T 12967.3-91 CASS Copper accelerated acid salt spray test
JOEO Salt spray chamber Laboratory simulated salt spray can be divided into three categories:
(1)Neutral salt spray test,(2) Acetate salt spray test,
(3)Copper salt accelerated acetate salt spray test
(1) The neutral salt spray test (NSS test) is the earliest and most widely used accelerated corrosion test method. It uses 5% sodium chloride salt water solution, and the PH value of the solution is adjusted to a neutral range (6.5 ~ 7.2) as a spray solution. The test temperature is 35℃, and the sedimentation rate of salt spray is required to be 1~2mL/80cm/h.
(2) Acetic acid salt spray test (ASS test) is developed on the basis of neutral salt spray test. It is to add some glacial acetic acid to the 5% sodium chloride solution, the pH value of the solution is reduced to about 3, the solution becomes acidic, and the salt mist formed finally becomes acidic from neutral salt mist. Its corrosion rate is about 3 times faster than the NSS test.
(3) The copper salt accelerated acetate spray test (CASS test) is a rapid salt spray corrosion test recently developed. The test temperature is 50℃. A small amount of copper salt-copper chloride is added to the salt solution to strongly induce corrosion. Its corrosion rate is about 8 times that of the NSS test.
Cooperation Customers Reference
JOEO salt spray chamber, salt spray tester testing products are standard in every major automobile manufacturer in North America. We are the leader in salt corrosion testing innovation and working with companies like the Daimler Group, Ford, GM, Honda, Hyundai, Nissan, and Toyota. JOEO Salt spray chamber service customers included many auto related suppliers such as Delphi, Visteon, Siemens, Valeo, Magni, Henkel, Borg Warner etc.Model | STC - 60 | STC - 90 | STC - 120 | STC - 160 | STC - 200 |
Internal Dimension WxHxD (mm) | 600450400 | 900500600 | 1200500800 | 1600500800 | 20005001000 |
External Dimension WxHxD(mm) | 11006001200 | 14009001300 | 190013001400 | 230013001400 | 270015001500 |
Lab Capacity(L) | 110 | 270 | 500 | 800 | 1500 |
Saline Capacity(L) | 15 | 25 | 40 | 40 | 40 |
Lab Temperature | Saline test (NSS ACSS) 35 ± 1℃; Corrosion Test (CASS) 50 ± 1℃ | ||||
Pressure Bucket Temperature | Saline test (NSS ACSS) 47 ± 1℃; Corrosion Test (CASS) 63 ± 1℃ | ||||
Saline Concentration | 5% concentration of NaCI, or every Liter 5% NaCI add 0.26g CuCI2H20 | ||||
Spray Volume | 1.0~2.0ml/ 80cm²/h (working at least 16 hours, and take the average value) | ||||
Spray Form | Continuous spraying or programmable spraying | ||||
Compressed Air Pressure(Kgf) | 1.0 ~ 6.0 | ||||
Power | AC 220V; 1∮ 3 lines | ||||
Approx. Weight (Kg) | 65 | 80 | 120 | 160 | 200 |